CASE HISTORY
NO. I6021
JUNE 2012
CLIENT:
Occidental Chemical Corp.
OXY Chem Niagara Plant
Niagara Falls, NY

UNIT:
First Effect Steam Chest Evaporator
771 tubes – 2 pass Vertical Heat Exchanger
3” O.D. x 10 BWG (0.134” Min. wall) Nickel 200 tubes

PROBLEM:

Extreme erosion/tube wall loss on 2nd pass tube inlets hampered reliability resulting in 42 tubes being plugged.


SOLUTION:

CTI installed 324 Shield/Seals constructed from Nickel 200, 12 inches long to fit the existing 3” OD x 10 BWG tubes. The erosion was severe but only limited to the first 6-8 inches of the tube ID’s at the upper tubesheet. The foot long Shield/Seals reinforced the damaged tubes and improved reliability of the Evaporator.


  • Case R1629 CASE HISTORY NO. R1629 MARCH 2008 CLIENT: BP West Coast Products LLC Cherry Point Refinery Blaine, Washington UNIT: #21-1325 Debutanizer Overhead Condenser 291 Finned... Read More
  • Case R80414 CASE HISTORY NO. R80414 NOVEMBER 2014 CLIENT: Shell Eastern Petroleum Pulau Bukom Refinery Singapore UNIT: E8515-16 Splitter Air Fin Cooler 230 Carbon Steel finned... Read More
  • Case R80094 CASE HISTORY NO. R80094 FEBRUARY 2014 CLIENT: Flint Hills Resources Corpus Christi West Plant Corpus Christi, TX UNIT: 26EA-2610 A,B & C First Effluent Condensers... Read More
  • Case I2104 CASE HISTORY NO. 12104 JANURARY 2009 CLIENT: Shell Philippines Exploration (SPEX) Malampaya On-Shore Gas Plant Batangas, Philippines UNIT: E-111 Inlet Gas Heater 193... Read More
  • Case R7573 CASE HISTORY NO. R7573 SEPTEMBER 2004 CLIENT: Conoco Phillips Sweeny Refinery Old Ocean, TX UNIT: Claus Boilers (2) 189 tubes each, Carbon Steel 2½” O.D. x 7... Read More
  • Case I146200 CASE HISTORY NO. I46200 / I40050 2001 - 2010 CLIENT: Dow Chemicals - Benelux Terneuzen, Holland UNIT: E220 Vertical Caustic Heat Exchanger 296 Tubes, Inconel 600 32mm... Read More
  • Case I3089 CASE HISTORY NO. I3089 JULY 2009 CLIENT: Celanese (Nanjing) Chemical Co. Nanjing, China UNIT: HE‐323 Vertical Acid Reboiler 812 tubes, Alloy C276 3/4” O.D. x .065”... Read More
  • Case I8262 CASE HISTORY NO. I8262 APRIL 1996 CLIENT: Aramco Uthmaniyah Gas Plant Dhahran, Saudi Arabia UNIT: Lean Solution Air Coolers Carbon Steel Tubes 1” O.D. x 14 BWG Design... Read More
  • Case I2012 CASE HISTORY NO. I2012 JUNE 2012 CLIENT: Chemtrade Logistics Beaumont Plant Beaumont, TX UNIT: E-1A Sulfuric Acid Heat Exchanger (vertical) 2,347- 304H stainless steel... Read More
  • CASE HISTORY NO. I6021 JUNE 2012 CLIENT: Occidental Chemical Corp. OXY Chem Niagara Plant Niagara Falls, NY UNIT: First Effect Steam Chest Evaporator 771... Read More
  • Case U51092 CASE HISTORY NO. U51092 APRIL 2012 CLIENT: Calpine Cumberland Energy Center Millville, NJ UNIT: Overhead Gas Air Fin Coolers 10 bundles with 492 carbon steel finned... Read More
  • Case R8092 CLIENT: ALON USA Krotz Springs Refinery Krotz Springs, LA UNIT: FCCU Flue Gas Heat Exchanger (vertical) 400 carbon steel tubes 2" O.D. x 9 BWG (0.148" Min. wall) x 40'... Read More

Ready To work with us? Contact us today!

or Give us a call 203-795-0070

Fields marked with * are required

PERSONAL DATA

YOUR REQUEST

Upload file... Number of files left: 3

Files: